Hot standby logreceiver errors if there are other logrecivers for the same logsender

A master stone's logsender does not correctly service multiple slave systems logreceivers, due to a logic error in code changes in v3.6.2.  If multiple logreceivers are connected to a single logsender, the data sent to the logreceivers will be out of sync, and the logreceivers will report validation errors.

Workaround

If you need a second slave system for the same master, start a second logsender on a different port to service the other slave.


                